Prosonic FMU4x FMU40

Brand: Endress+Hauser

Prosonic FMU4x FMU40

Brand: Endress+Hauser

Vector, Endress+Hauser's exclusive USA representative in:
Northwest AR South IL KS  MO East NM OK  TX

Extended Extended

Specs at a Glance

Process temperature:
-40 °C ... 80 °C
(-40 °F ... 176 °F)
Max. measurement distance:
Liquids: 5 m (16 ft),
Solids: 2 m (6.6 ft)
Main wetted parts:
PVDF
Process pressure / max. overpressure limit:
0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
Accuracy:
+/- 2 mm or +/- 0.2 % of set measuring range 1)

Field of application

The Prosonic M FMU40 is a two-wire or four-wire compact transmitter for non-contact ultrasonic level measurement of liquids and bulk solids in sophisticated applications. The ultrasonic sensor uses the Time-of-Flight method

Specifications

Industry

  • Chemical
  • Water, Wastewater & Waste
  • Food & Beverage
  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Pulp & Paper (incl. Printing)

Product Family

  • Prosonic

Continuous / Liquids

Characteristic / Application

  • Compact ultrasonic transmitter

Supply / Communication

  • 2-wire HART

Accuracy

  • +/- 2 mm or +/- 0.2 % of set measuring range

Ambient temperature

  • -40 °C ... 80 °C
  • (-40 °F ... 176 °F)

Process temperature

  • -40 °C ... 80 °C
  • (-40 °F ... 176 °F)

Process pressure / max. overpressure limit

  • 0.7 bar ... 3 bar abs
  • (10 psi ... 44 psi)

Main wetted parts

  • PVDF

Process connection

  • G / NPT 1 1/2"

Blocking distance

  • 0.25 m (0.8 ft)

Max. measurement distance

  • Liquids: 5 m (16 ft),
  • Solids: 2 m (6.6 ft)

Communication

  • 4...20 mA HART

Certificates / Approvals

  • ATEX, FM, CSA, IEC, INMETRO, NEPSI

Application limits

  • For higher resistance:
  • FMU42/FDU9x
  • Foam / high turbulence possible:
  • FMU41/FDU91
  • Fast filling and discharging rate:
  • FMU90 + FDU9x
  • Level limit detection:

Continuous / Solids

Characteristic / Application

  • Compact ultrasonic transmitter

Supply / Communication

  • 2-wire HART

Accuracy

  • +/- 2 mm or +/- 0.2 % of set measuring range 1)

Ambient temperature

  • -40 °C ... 80 °C
  • (-40 °F ... 176 °F)

Process temperature

  • -40 °C ... 80 °C
  • (-40 °F ... 176 °F)

Process pressure / max. overpressure limit

  • 0.7 bar ... 3 bar abs
  • (10 psi ... 44 psi)

Main wetted parts

  • PVDF

Process connection

  • G / NPT 1 1/2"

Blocking distance

  • 0.25 m (0.8 ft)

Max. measurement distance

  • Liquids: 5 m (16 ft),
  • Solids: 2 m (6.6 ft)

Communication

  • 4...20 mA HART

Certificates / Approvals

  • ATEX, FM, CSA, IEC, INMETRO, NEPSI

Application limits

  • Take notice of range diagram

Liquids

Product headline

  • Compact ultrasonic measuring instrument
  • Cost effective solution for open channel

Max. measurement error

  • > 2 mm depending on flow application

Measuring range

  • 0.25...5 m [0.8...16 ft]

Max. process pressure

  • 0.7 bar...3 bar (10 psi...44 psi)

Medium temperature range

  • -40°C ... 80°C
  • (-40°F...176°F)

Degree of protection

  • IP68

Outputs

  • 4...20 mA HART

Inputs

  • 2-wire

Digital communication

  • HART

Hazardous area approvals

  • ATEX, IEC, FM, CSA, INMETRO, NEPSI
show more