Liquid Analysis

Comprehensive product range for all analytical parameters.

1 - 48 of 188 Products
Digital pH Sensor Memosens CPL51E
Endress+Hauser
CPL51E_s_20.01._001.png
Fundamental Fundamental
Request Information
Multiparameter Handheld Liquiline Mobile CML18
Endress+Hauser
Liquiline Mobile CML18_s_stehend_001.png
Lean Lean
Request Information
Digital Extension Cable Memosens CYK11
Endress+Hauser
Digital extension cable CYK11
Request Information
Flow Assembly CYA680
Endress+Hauser
Flow assembly CYA680
Request Information
Digital Service and Qualification Tool Memocheck Sim CYP03D
Endress+Hauser
Digital service and qualification tool Memocheck Sim CYP03D
Request Information
1-Channel Transmitter Liquiline CM72
Endress+Hauser
Liquiline Compact CM72_angular.png
Request Information
Automatic Water Sampler for North America Liquistation CSF34
Endress+Hauser
Automatic water sampler for North America Liquistation CSF34
Request Information
Analog Conductivity Sensor Condumax CLS13
Endress+Hauser
Analog conductivity sensor Condumax CLS13
Request Information
Ex-Certified Multiparameter Handheld Liquiline To Go CYM291
Endress+Hauser
LiquilineTo Go CYM291.png
Request Information
Calibration Tool for Conductivity Sensors Conducal CLY421
Endress+Hauser
Calibration tool for conductivity sensors Conducal CLY421
Request Information
Analog Conductivity Sensor Indumax CLS54
Endress+Hauser
Analog conductivity sensor Indumax CLS54
Request Information
8-Channel Transmitter Liquiline CM448
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Analog Conductivity Sensor Condumax CLS15
Endress+Hauser
Analog conductivity sensor Condumax CLS15
Request Information
Ultrasonic Cleaning System CYR52
Endress+Hauser
Ultrasonic cleaning system CYR52
Request Information
Aluminum Analyzer Liquiline System CA80AL
Endress+Hauser
Aluminum analyzer Liquiline System CA80AL
Extended Extended
Request Information
Digital ORP Sensor Orbipore CPS92D
Endress+Hauser
CPS92D-7PB21 - 001.png
Request Information
1-Channel Transmitter Liquiline CM14
Endress+Hauser
cm14_12_04_2011_007_pH.png
Fundamental Fundamental
Request Information
Digital Ammonium and Nitrate Sensor ISEmax CAS40D
Endress+Hauser
Digital ammonium and nitrate sensor ISEmax CAS40D
Extended Extended
Request Information
Digital 4-electrode Conductivity Sensor Memosens CLS82E
Endress+Hauser
Digital 4-electrode conductivity sensor Memosens CLS82E
Extended Extended
Request Information
Digital pH Sensor Orbisint CPS11D
Endress+Hauser
CPS11D_Ex_front.png
Extended Extended
Request Information
Digital Conductivity Sensor Indumax CLS54D
Endress+Hauser
Digital conductivity sensor Indumax CLS54D
Extended Extended
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA472D
Endress+Hauser
CPA472D_front.png
Request Information
Digital Combined pH/ORP Sensor Memosens CPS96E
Endress+Hauser
CPS96E-combined-pH-ORP-sensor-Beauty.png
Extended Extended
Request Information
UV Absorption Sensor OUSAF46
Endress+Hauser
UV absorption sensor OUSAF46
Extended Extended
Request Information
Digital Oxygen Sensor Oxymax COS61D
Endress+Hauser
Digital oxygen sensor Oxymax COS61D
Extended Extended
Request Information
VARIVENT Assembly for Process Photometers CUA261
Endress+Hauser
VARIVENT assembly for process photometers CUA261
Request Information
Sample Preparation Stamoclean CAT411
Endress+Hauser
Sample preparation Stamoclean CAT411
Request Information
Turbidity Sensor Turbimax CUS52D
Endress+Hauser
Turbidity sensor Turbimax CUS52D
Extended Extended
Request Information
Ultrasonic Interface Sensor Turbimax CUS71D
Endress+Hauser
Ultrasonic interface sensor Turbimax CUS71D
Extended Extended
Request Information
Digital pH Sensor Memosens CPL59E
Endress+Hauser
Memosens CPL59E.png
Request Information
Digital ORP Sensor Memosens CPS12E
Endress+Hauser
CPS12E-ORP-sensor-platinum-cap.png
Extended Extended
Request Information
Automatic Water Sampler Liquistation CSF48
Endress+Hauser
Automatic water sampler Liquistation CSF48
Extended Extended
Request Information
Turbidity Assembly Flowfit CUA252
Endress+Hauser
Turbidity assembly Flowfit CUA252
Request Information
Digital Conductivity Sensor Memosens CLS21E
Endress+Hauser
Digital conductivity sensor Memosens CLS21E
Extended Extended
Request Information
Suspended Solids and Color Sensor OUSAF12
Endress+Hauser
Suspended solids and color sensor OUSAF12
Extended Extended
Request Information
Analog Conductivity Sensor Indumax CLS50
Endress+Hauser
Analog conductivity sensor Indumax CLS50
Request Information
Conductivity Assembly Dipfit CLA111
Endress+Hauser
Conductivity assembly Dipfit CLA111
Request Information
Flow Assembly Flowfit CPA25
Endress+Hauser
Flow assembly Flowfit CPA25
Lean Lean
Request Information
Analog Conductivity Sensor Condumax CLS21
Endress+Hauser
Analog conductivity sensor Condumax CLS21
Request Information
Digital Free Chlorine Sensor Memosens CCS51E
Endress+Hauser
Digital free chlorine sensor Memosens CCS51E
Extended Extended
Request Information
Process Assembly Unifit CPA842
Endress+Hauser
CPA842_front_with cable protection.png
Request Information
8-Channel Transmitter Liquiline CM448R
Endress+Hauser
CM448R.png
Extended Extended
Request Information
Multichannel Transmitter Liquiline CM44P
Endress+Hauser
Liquiline_CM44P_AU.png
Extended Extended
Request Information
Flow Assembly for Multi-Parameter Measurements Flowfit CYA27
Endress+Hauser
Flow assembly for multi-parameter measurements Flowfit CYA27
Request Information
Conductivity Assembly Dipfit CLA140
Endress+Hauser
Conductivity assembly Dipfit CLA140
Request Information
pH Buffer CPY20
Endress+Hauser
CPY20 pH buffers.png
Request Information
Digital Combined pH/ORP Sensor Memosens CPS96D
Endress+Hauser
CPS96D_01s_7BT21.png
Request Information
Digital ORP Sensor Ceragel CPS72D
Endress+Hauser
CPS72D-G-7PT21.png
Request Information

Liquid Analysis

Endress+Hauser’s Liquid Analysis portfolio spans the complete measurement chain required to make water and process‑liquid quality visible, controllable, and compliant, from rugged in‑situ sensors and modular transmitters to wet‑chem analyzers, samplers, and application‑specific assemblies. At its core are measurement families covering pH/ORP, conductivity (contacting and inductive), dissolved oxygen, chlorine and related disinfectants, turbidity and solids content, UV absorption (e.g., SAC254), and nutrients such as ammonium, nitrate, and phosphate. Surrounding these are standardized platforms for installation, data acquisition, and diagnostics so that a plant can build from a single loop to a fleet of measuring points with consistent operation and lifecycle practices. In short: it’s a portfolio designed to help systems designers, plant engineers, and operators reduce risk and operating cost while improving process stability and product and environmental quality. Endress+Hauser describes this offering as a full suite of sensors, transmitters, assemblies, analyzers, and services for liquid analysis across industries and utilities.

A key enabler across the portfolio is Memosens digital sensor technology. Unlike classical analog probes, Memosens converts the measured signal to digital at the sensor head and transfers it inductively (non‑contact) to the cable and transmitter. This galvanically isolated, hermetically sealed coupling makes the connection immune to moisture ingress, corrosion, and salt bridges and eliminates ground loops, a frequent source of drift and downtime in harsh environments. The practical impact for operations is substantial: probes can be calibrated in the lab under controlled conditions, then swapped in the field (“plug & play”) with traceable calibration histories and predictive diagnostics traveling with the sensor. Memosens 2.0 extends these functions to larger data sets and IIoT use cases (e.g., cloud access and asset health dashboards), while maintaining the handling simplicity operators value during routine maintenance.

For measurement integration, Liquiline multiparameter transmitters provide a common platform and user experience from single‑loop panels to complex, multi‑channel skids. A Liquiline device recognizes connected Memosens sensors automatically, loads the correct parameter menus, and supports straightforward commissioning via a consistent HMI. The CM44x family scales from one or two channels up to four (and beyond, depending on model), and modules can be added at any time to expand channels, I/O, relays, or fieldbus interfaces. Critically for mixed parameter stations, the same controller can host pH/ORP, conductivity, oxygen, chlorine, turbidity, sludge level, nitrate, and UV absorption, as well as selected process photometers, reducing cabinet footprint and spare‑part variety. Heartbeat Technology within the platform adds continuous self‑diagnostics and guided verification to document measurement integrity without process interruption, supporting both quality management and regulatory audits.

When processes require wet‑chemistry for compliance and optimization, Liquiline System CA80‑series analyzers deliver online measurement of nutrients and “sum parameters.” Typical variants include orthophosphate for chemical dosing control, ammonium and nitrate for biological treatment optimization, and total nitrogen for permit reporting or load‑based control strategies. The analyzers share the Liquiline platform’s service concept: automatic calibration and cleaning routines, low reagent consumption to curb operating cost, and remote diagnostics to reduce unplanned visits. Importantly, a CA80 can be extended with up to four additional Memosens sensors, turning an analyzer cabinet into a compact, multiparameter station that correlates chemical concentrations with key field parameters (e.g., pH, DO, conductivity) for better cause‑and‑effect understanding. For plant engineers, this means fewer boxes, fewer drawings, and one common spare‑parts and training model; for operators, it means a familiar UI and clear maintenance prompts.

Sampling, whether for regulatory compliance, process incident investigations, or laboratory corroboration of online readings, is covered by Liquistation (stationary) and Liquiport (portable) samplers. These systems support time‑, flow‑, and event‑based sampling routines and are designed to preserve sample integrity with controlled storage and standards‑compliant workflows. In monitoring networks and plant headworks, a Liquistation can be configured to trigger on setpoints (e.g., turbidity or pH excursions) and, when desired, upgraded by adding Memosens sensors directly into the sampler cabinet. This collapses what is often a sprawl of boxes into one robust enclosure and simplifies power and communications. For field campaigns, the two‑piece Liquiport design and optional battery power facilitate safe transport and operation in remote locations. Together, these devices enable defensible sampling programs that integrate seamlessly with continuous measurements, improving traceability from the process to the lab bench.

Robust measurement begins with correct installation, and Endress+Hauser’s assemblies and holders translate instrument capability into process‑reliable data. Flowfit CYA27 creates a controlled bypass for multi‑parameter measurements, chlorine and other disinfectants, pH/ORP, conductivity, and dissolved oxygen, with built‑in flow monitoring to ensure the sensor is in spec and to protect against dry‑run or fouling effects. In open basins, channels, and tanks, Flexdip immersion systems and modular holders allow fixed, chain, or free‑swinging mounts that can be reconfigured as needs evolve. Where access is limited or the medium is abrasive, fibrous, or scaling, Cleanfit retractable assemblies let you insert, retract, clean, and even calibrate sensors under process pressure, reliably isolating the process with integrated valves and seals, so maintenance no longer forces a shutdown. Hygienic, fully sterilizable variants serve life sciences and food plants, while heavy‑duty versions address chemical, oil & gas, and wastewater service.

For high‑purity and thermal‑cycle applications, engineered solutions like the SWAS (Steam and Water Analysis System) Compact panel combine proven sensors, optimized sample conditioning, and space‑efficient hydraulics to continuously monitor conductivity (including cation conductivity), pH, and dissolved oxygen at low sample flow. The purpose is to detect ingress or chemistry upsets early, before they translate into turbine, boiler, or heat‑exchanger damage, while lowering utilities consumption and sample‑panel footprint. The standardized panel approach speeds specification, installation, and qualification and brings the same Liquiline HMI and Memosens service model to utility water that operators experience elsewhere in the plant. This is representative of how the Liquid Analysis portfolio packages the building blocks into application‑ready systems that shorten project schedules and simplify lifecycle support.

What this means in practice is a set of measurable gains across industries. In municipal and industrial wastewater treatment, online pH/ORP and conductivity stabilize neutralization and sludge dewatering; optical DO accelerates aeration control response, wringing energy out of blowers without compromising biology; orthophosphate and ammonium analyzers make chemical dosing and nitrification/denitrification control predictable and auditable; turbidity and SAC254 support filter performance and early organics detection. In drinking and process water, free‑chlorine or chlorine‑dioxide measurement under controlled flow extends disinfection assurance into remote zones of distribution systems or recycle loops. In food & beverage, hygienic pH and conductivity support CIP validation and phase separation; low‑oxygen monitoring protects flavor and shelf life; retractable assemblies reduce intervention time on viscous, sticky, or abrasive products. Power and life‑science utilities use SWAS‑style panels to safeguard assets and batch quality. Mining, pulp & paper, and chemicals leverage rugged installations and retractable hardware to maintain uptime in abrasive or fouling media. Across these scenarios, the common Liquiline/Memosens backbone reduces training load, simplifies spare‑parts stocking, and improves data consistency for historians, DCS/PLC, and cloud analytics.

Designing with this portfolio is straightforward: specify the parameter and operating range, choose the appropriate Memosens sensor family and body material, pair it with a Liquiline transmitter sized to the channel count and I/O strategy, and select an assembly matched to the hydraulics (bypass, immersion, or retractable) and sanitary or hazardous‑area requirements. Add a CA80‑series analyzer where chemistry is the control variable or a sampler where physical evidence is required. From there, standardize around lab calibration of spare probes, use Heartbeat verification to extend maintenance intervals with documented proof‑tests, and exploit modularity to add sensors as needs evolve (e.g., correlating DO with ammonium load, or pH with orthophosphate). The result is fewer custom one‑offs, faster operator onboarding, clearer maintenance prompts, and a measurement fleet that scales from a single skid to a plantwide network under a unified operating model, precisely the terrain where Endress+Hauser’s Liquid Analysis offering is engineered to excel.

Vector, your Authorized Endress+Hauser Representative