Specs at a Glance

Process pressure / max. overpressure limit:
0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
Process temperature:
-40 °C ... 95 °C
(-40 °F ... 203 °F)
Max. measurement distance:
Liquids: 20 m (65 ft),
Solids: 10 m (33 ft)
Accuracy:
+/- 2mm + 0.17% of measured distance
Main wetted parts:
PVDF (fully welded IP68 / NEMA 6P)

Field of application

The FDU92 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 20m (65ft), solids 10m (33ft).

Key Benefits

  • Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present
  • Hermetically welded PVDF sensor for highest chemical resistance
  • Suited for rough ambient conditions thanks to separate installation from the transmitter (up to 300m)
  • Reduced build-up formation because of the self-cleaning effect
  • Integrated automatic sensor detection for transmitters FMU90/FMU95 for simple commissioning

Specifications

Industry

  • Chemical
  • Water, Wastewater & Waste
  • Food & Beverage
  • Power & Energy
  • Mining, Minerals & Metals

Product Family

  • Prosonic

Continuous / Liquids

Characteristic / Application

  • Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

Supply / Communication

  • 4-wire (HART, PROFIBUS DP)

Accuracy

  • +/- 2mm + 0.17% of measured distance

Ambient temperature

  • -40 °C ... 95 °C
  • (-40 °F ... 203 °F)

Process temperature

  • -40 °C ... 95 °C
  • (-40 °F ... 203 °F)

Process pressure / max. overpressure limit

  • 0.7 bar ... 4 bar abs
  • (10 psi ... 58 psi)

Main wetted parts

  • PVDF (fully welded IP68 / NEMA 6P)

Process connection

  • G / NPT 1"

Blocking distance

  • 0.4 m (1.3 ft)

Max. measurement distance

  • Liquids: 20 m (65 ft),
  • Solids: 10 m (33 ft)

Communication

  • Transmitter:
  • 4 ... 20 mA HART
  • PROFIBUS DP

Certificates / Approvals

  • ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex

Options

  • Second 4...20 mA output

Components

  • Transmitter:
  • FMU90, FMU95

Application limits

  • For tank farms scanner:
  • FMU95

Continuous / Solids

Characteristic / Application

  • Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

Supply / Communication

  • 4-wire (HART, PROFIBUS DP)

Accuracy

  • +/- 2mm + 0.17% of measured distance

Ambient temperature

  • -40 °C ... 95 °C
  • (-40 °F ... 203 °F)

Process temperature

  • -40 °C ... 95 °C
  • (-40 °F ... 203 °F)

Process pressure / max. overpressure limit

  • 0.7 bar ... 4 bar abs
  • (10 psi ... 58 psi)

Main wetted parts

  • PVDF (fully welded IP68 / NEMA 6P)

Process connection

  • G / NPT 1"

Blocking distance

  • 0.4 m (1.3 ft)

Max. measurement distance

  • Liquids: 20 m (65 ft),
  • Solids: 10 m (33 ft)

Communication

  • Transmitter:
  • 4 ... 20 mA HART
  • PROFIBUS DP

Certificates / Approvals

  • ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex

Options

  • Second 4...20mA output

Components

  • Transmitter:
  • FMU90

Liquids

Product headline

  • Ultrasonic sensor for level and open channel flow measurement.
  • For applications requiring separate level / open channel flow measurement system.

Max. measurement error

  • accuracy:
  • distance measurement: +/- 2mm + 0.17%

Measuring range

  • Up to 20m / 65ft

Max. process pressure

  • 0.4 bar...4 bar
  • (10 psi...58 psi)

Medium temperature range

  • -40...95°C
  • (-40...203°F)

Degree of protection

  • IP68

Display/Operation

  • Transmitter FMU90

Outputs

  • Transmitter:
  • 4...20mA HART
  • PROFIBUS DP

Inputs

  • Transmitter FMU90

Digital communication

  • HART, PROFIBUS DP

Hazardous area approvals

  • ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
show more