Prosonic FDU9x FDU92
Brand: Endress+HauserProsonic FDU9x FDU92
Brand: Endress+Hauser
Extended Specs at a Glance
Process pressure / max. overpressure limit:
0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
(10 psi ... 58 psi)
Process temperature:
-40 °C ... 95 °C
(-40 °F ... 203 °F)
(-40 °F ... 203 °F)
Max. measurement distance:
Liquids: 20 m (65 ft),
Solids: 10 m (33 ft)
Solids: 10 m (33 ft)
Accuracy:
+/- 2mm + 0.17% of measured distance
Main wetted parts:
PVDF (fully welded IP68 / NEMA 6P)
Field of application
The FDU92 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 20m (65ft), solids 10m (33ft).
Key Benefits
- Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present
- Hermetically welded PVDF sensor for highest chemical resistance
- Suited for rough ambient conditions thanks to separate installation from the transmitter (up to 300m)
- Reduced build-up formation because of the self-cleaning effect
- Integrated automatic sensor detection for transmitters FMU90/FMU95 for simple commissioning
Specifications
Brand
Industry
- Chemical
- Water, Wastewater & Waste
- Food & Beverage
- Power & Energy
- Mining, Minerals & Metals
Product Family
- Prosonic
Continuous / Liquids
Characteristic / Application
- Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
Supply / Communication
- 4-wire (HART, PROFIBUS DP)
Accuracy
- +/- 2mm + 0.17% of measured distance
Ambient temperature
- -40 °C ... 95 °C
- (-40 °F ... 203 °F)
Process temperature
- -40 °C ... 95 °C
- (-40 °F ... 203 °F)
Process pressure / max. overpressure limit
- 0.7 bar ... 4 bar abs
- (10 psi ... 58 psi)
Main wetted parts
- PVDF (fully welded IP68 / NEMA 6P)
Process connection
- G / NPT 1"
Blocking distance
- 0.4 m (1.3 ft)
Max. measurement distance
- Liquids: 20 m (65 ft),
- Solids: 10 m (33 ft)
Communication
- Transmitter:
- 4 ... 20 mA HART
- PROFIBUS DP
Certificates / Approvals
- ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options
- Second 4...20 mA output
Components
- Transmitter:
- FMU90, FMU95
Application limits
- For tank farms scanner:
- FMU95
Continuous / Solids
Characteristic / Application
- Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Supply / Communication
- 4-wire (HART, PROFIBUS DP)
Accuracy
- +/- 2mm + 0.17% of measured distance
Ambient temperature
- -40 °C ... 95 °C
- (-40 °F ... 203 °F)
Process temperature
- -40 °C ... 95 °C
- (-40 °F ... 203 °F)
Process pressure / max. overpressure limit
- 0.7 bar ... 4 bar abs
- (10 psi ... 58 psi)
Main wetted parts
- PVDF (fully welded IP68 / NEMA 6P)
Process connection
- G / NPT 1"
Blocking distance
- 0.4 m (1.3 ft)
Max. measurement distance
- Liquids: 20 m (65 ft),
- Solids: 10 m (33 ft)
Communication
- Transmitter:
- 4 ... 20 mA HART
- PROFIBUS DP
Certificates / Approvals
- ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options
- Second 4...20mA output
Components
- Transmitter:
- FMU90
Liquids
Product headline
- Ultrasonic sensor for level and open channel flow measurement.
- For applications requiring separate level / open channel flow measurement system.
Max. measurement error
- accuracy:
- distance measurement: +/- 2mm + 0.17%
Measuring range
- Up to 20m / 65ft
Max. process pressure
- 0.4 bar...4 bar
- (10 psi...58 psi)
Medium temperature range
- -40...95°C
- (-40...203°F)
Degree of protection
- IP68
Display/Operation
- Transmitter FMU90
Outputs
- Transmitter:
- 4...20mA HART
- PROFIBUS DP
Inputs
- Transmitter FMU90
Digital communication
- HART, PROFIBUS DP
Hazardous area approvals
- ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex