Gammapilot FMG50
Brand: Endress+HauserGammapilot FMG50
Brand: Endress+Hauser
Xpert
Heartbeat Technology Specs at a Glance
Main wetted parts:
Non-contact
Process temperature:
Any
Accuracy:
+/-1%
Process pressure / max. overpressure limit:
Any
Max. measurement distance:
Unlimited measuring range,
Cascade
Cascade
Field of application
The Gammapilot FMG50 compact transmitter is designed for non-contact point level detection, continuous level, interface and density measurement in liquids, solids, suspensions or sludges. As the first true 2-wire loop powered compact transmitter it minimizes engineering and installation efforts.
For all kinds of process vessels, like reactors, autoclaves, separators, acid tanks, cyclones
For liquids, solids, suspensions or sludges etc.
Extreme measuring conditions, for example corrosion, abrasion, viscosity, toxicity
Process temperature: No limitation (non-invasive)
Process pressure: No limitation (non-invasive)
Housing material: 316L, aluminum
International explosion protection certificates, SIL, overfill prevention WHG
Key Benefits
- First real 2-wire loop-powered compact transmitter minimizes engineering and installation efforts
- Reduced installation and engineering costs thanks to the first 2-wire loop powered compact transmitter
- Increased plant safety, efficiency and availability even under extreme process and ambient conditions
- Designed according to IEC 61508 with SIL2/3 approval for all measuring tasks
- Reduced verification effort and minimized plant shut-downs due to state-of-art Heartbeat Technology
- Usage in up to +80°C (+176°F) ambient temperature without additional cooling thanks to innovative sensor technology
- Bluetooth® wireless technology for remote operation out of the radiation beam
Specifications
Brand
Industry
- Chemical
- Power & Energy
- Mining, Minerals & Metals
- Oil & Gas
- Pulp & Paper (incl. Printing)
Continuous / Liquids
Characteristic / Application
- Compact transmitter for extreme process conditions (temperature, pressure);
- Non-contact measuring technique
Interface measurement
- Interfaces liquid / liquid also with emulsion layers
- Interfaces liquid / solid
Specialities
- Heartbeat Technology,
- SIL 2/3 according to IEC 61508,
- Bluetooth® commissioning, operation and maintenance with the SmartBlue App
Supply / Communication
- 2-wire loop powered
Accuracy
- +/-1%
Ambient temperature
- -40 °C...+80 °C,
- (-40 °F...+176 °F)
Process temperature
- Any
Process pressure / max. overpressure limit
- Any
Main wetted parts
- Non-contact
Process connection
- Non-contact
Sensor length
- PVT scintillator
- 400 mm...3000 mm,
- >3000 mm cascade mode
Max. measurement distance
- Unlimited measuring range,
- Cascade
Communication
- 4...20 mA HART
Certificates / Approvals
- ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
Safety approvals
- Overfill protection WHG
- SIL 2/3
Design approvals
- EN 10204-3.1
Options
- Display
Components
- Isotope: FSG60, FSG61,
- Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
- Mounting accessories: FHG61
Continuous / Solids
Characteristic / Application
- Compact transmitter for extreme process conditions (temperature, pressure);
- Non-contact measuring technique
Specialities
- Heartbeat Technology,
- SIL 2/3 according to IEC 61508,
- Bluetooth® commissioning, operation and maintenance with the SmartBlue App
Supply / Communication
- 2-wire loop powered
Accuracy
- +/-1%
Ambient temperature
- -40 °C...+80 °C,
- (-40 °F...+176 °F)
Process temperature
- Any
Process pressure / max. overpressure limit
- Any
Main wetted parts
- Non-contact
Process connection
- Non-contact
Sensor length
- PVT scintillator
- 400 mm...3000 mm,
- >3000 mm cascade mode
Max. measurement distance
- Unlimited measuring range,
- Cascade
Communication
- 4...20 mA HART
Certificates / Approvals
- ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
Safety approvals
- Overfill protection WHG
- SIL 2/3
Design approvals
- EN 10204-3.1
Options
- Display
Components
- Isotope: FSG60, FSG61,
- Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
- Mounting accessories: FHG61
Density
Characteristic / Application
- Compact transmitter for extreme process conditions (temperature, pressure);
- Non-contact measuring technique
Supply / Communication
- 2-wire loop powered
Ambient temperature
- -40 °C...+80 °C,
- (-40 °F...+176 °F)
Process temperature
- Any
Process pressure
- Any
Wetted parts
- Non-contact
Sensor length
- PVT scintillator:
- 200 mm...400 mm,
- NAI scintillator:
- 50 x 50 mm,
- 50 x 100 mm
Output
- 4...20 mA HART
Certificates / Approvals
- ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
Options
- Display
Specialities
- Heartbeat Technology,
- SIL 2/3 according to IEC 61508,
- Bluetooth® commissioning, operation and maintenance with the SmartBlue App
Components
- Isotope: FSG60, FSG61,
- Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
- Mounting accessories: FHG61
Point Level / Liquids
Characteristic / Application
- Compact transmitter for extreme process conditions (temperature, pressure);
- Non-contact measuring technique
Specialities
- Heartbeat Technology,
- SIL 2/3 according to IEC 61508,
- Bluetooth® commissioning, operation and maintenance with the SmartBlue App
Supply / Communication
- 2-wire loop powered
Ambient temperature
- -40 °C...+80 °C,
- (-40 °F...+176 °F)
Process temperature
- Any
Process pressure / max. overpressure limit
- Any
Main wetted parts
- Non-contact
Process connection
- Non-contact
Sensor length
- PVT scintillator:
- 200 mm...400 mm,
- NAI scintillator:
- 50 x 50 mm,
- 50 x 100 mm
Communication
- 4...20 mA HART
Certificates / Approvals
- ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
Safety approvals
- Overfill protection WHG
- SIL 2/3
Design approvals
- EN 10204-3.1
Options
- Display
Components
- Isotope: FSG60, FSG61,
- Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
- Mounting accessories: FHG61
Point Level / Solids
Characteristic / Application
- Compact transmitter for extreme process conditions (temperature, pressure);
- Non-contact measuring technique
Specialities
- Heartbeat Technology,
- SIL 2/3 according to IEC 61508,
- Bluetooth® commissioning, operation and maintenance with the SmartBlue App
Supply / Communication
- 2-wire loop powered
Ambient temperature
- -40 °C...+80 °C,
- (-40 °F...+176 °F)
Process temperature
- Any
Process pressure / max. overpressure limit
- Any
Main wetted parts
- Non-contact
Process connection
- Non-contact
Sensor length
- PVT scintillator:
- 200 mm...400 mm,
- NAI scintillator:
- 50 x 50 mm,
- 50 x 100 mm
Communication
- 4...20 mA HART
Certificates / Approvals
- ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
Safety approvals
- Overfill protection WHG
- SIL 2/3
Design approvals
- EN 10204-3.1
Options
- Display
Components
- Isotope: FSG60, FSG61,
- Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
- Mounting accessories: FHG61