Micropilot NMR84
Brand: Endress+HauserMicropilot NMR84
Brand: Endress+Hauser
Xpert Specs at a Glance
(-40°F...302°F)
For calibration to regulatory standards:
30 m (98 ft)
Field of application
Micropilot NMR84 is used for custody transfer and inventory control applications with NMi- and PTB-approvals. It meets the relevant requirements according to OIML R85 and API 3.1B. The NMR84 free space radar with drip-off planar antenna is specifically suited for stilling well applications. The superior drip-off antenna design with proven track record eliminates problems caused by condensation.
With planar antenna particularly suited for stilling well applications.
Process connections: Flanges
Temperature: -40 to +150°C (-40 to +302°F)
Pressure: Vacuum to +25bar (Vacuum to +362psi)
Maximum measuring range: 40m (131ft)
Accuracy: ±0.5mm (±0.02")
Transmitting frequency: 6GHz
International explosion protection and custody transfer certificates, overfill prevention WHG, SIL
Key Benefits
- Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy) for high level of safety
- Maximum reliability through accuracy up to ±0.5mm (±0.02")
- Developed according to international metrology recommendations such as OIML R85 and API MPMS
- Local and country-specific certifications like NMi or PTB for custody transfer applications
- Simplified installation and trouble-free operations due to easy connection to major DCS systems via open protocols
- Unique drip-off antenna design eliminates measurement error due to condensation build-up
Specifications
Brand
Industry
- Chemical
- Food & Beverage
- Oil & Gas
Product Family
- Micropilot
Continuous / Liquids
Characteristic / Application
- Planar antenna, 6GHz: High precision measurement for for storage tanks up to 30 m (98ft)
Specialities
- Custody transfer level measurement
Supply / Communication
- 85-264VAC
- 52-74VAC
- 19-64VDC
Accuracy
- up to 0.5 mm
Ambient temperature
- Standard:
- -40°C…60°C
- (-40°F...140°F)
- For calibration to regulatory
- standards:
- -25°C…55°C
- (-13°F...131°F)
Process temperature
- -40°C…150°C
- (-40°F...302°F)
Process pressure / max. overpressure limit
- Vacuum ... 25 bar abs
Main wetted parts
- 316L, PTFE
Process connection
- Flange:
- DN100/4"…DN300/12"
- UNI-Flange:
- DN150/6"…DN300/12"
Max. measurement distance
- 40 m (131 ft)
- For calibration to regulatory standards:
- 30 m (98 ft)
Communication
- Outputs:
- Fieldbus: Modbus RS485, V1, WM550
- HART, BPM and TRL/2 (via GE option)
- Analog 4-20mA output (Exi/ Exd)
- Relay output (Exd)
- Inputs:
- Analog 4-20mA input (Exi/ Exd)
- 2-, 3-, 4-wire RTD input
- Discrete input (Exd, passive/ active)
Certificates / Approvals
- ATEX, FM, IEC Ex, EAC, JPN Ex, KC Ex,
- INMETRO, NEPSI, UK Ex
Safety approvals
- Overfill protection WHG
- SIL
Design approvals
- EN 10204-3.1
- NACE MR0175, MR0103
- AD2000
Metrological approvals and certificates
- OIML, NMi, PTB
Options
- Redundant fieldbus
- Alu-coated or 316L housing
- Weather protection cover
Application limits
- Maximum measuring range is
- dependent on the tank form and/
- or application
- Strong condensate or build-up
- formation