Solicap FTI5x FTI56
Brand: Endress+HauserSolicap FTI5x FTI56
Brand: Endress+Hauser
Extended Specs at a Glance
(Vacuum ... 362 psi)
(-58°F ... 356°F)
Field of application
Solicap FTI56 is a fully/partly insulated and robust rope probe for point level detection of fine-grained to coarse-grained bulk solids. It offers maximum reliability and is suited for a wide range of applications thanks to numerous certificates and approvals. Due to its robust construction, it can also be used to provide accurate measurements in applications with very high tensile loads up to 60kN.
For applications with very high tensile loads up to 60kN. Fieldgate and Solicap represent a solution for material provisioning and logistical optimization (inventory control).
Process connections: Flanges and threads
Measurement range: 500 to 22,000mm (20 to 866")
Temperature: -50 to +180°C (-58 to +356°F)
Pressure: -1 to +25bar (-14.5 to +363psi)
International explosion protection certificates, SIL
Key Benefits
- Extremely robust design for harsh process conditions
- Cost savings thanks to easy and fast commissioning as calibration is performed at the press of a button
- Universal application thanks to wide range of certificates and approvals
- Two-stage overvoltage protection against static discharges from the silo
- Increased safety due to permanent automatic monitoring of electronics
- Reduction in storage costs thanks to easy-to-shorten rod model (for partial insulation) and rope model (for partial and full insulation)
Specifications
Brand
Industry
- Chemical
- Food & Beverage
- Power & Energy
- Mining, Minerals & Metals
Product Family
- Solicap
Point Level / Solids
Characteristic / Application
- Fully / partly isulated rope probe for small-grain / large-grain solids
- Simple calibration
- Suitable for abrasive media
- Very robust probe
Specialities
- Inactive length
- High tensile loading
- Extremely robust probe
Supply / Communication
- 19 ... 253V AC
- 10 ... 55V DC-PNP
- 19...253V AC bzw 10...55V DC
- 8/16mA, 11 ... 36V DC
- PFM
- 3-wire
Ambient temperature
- -50°C ... 70°C
- (-58°F ... 158°F)
Process temperature
- -50°C ... 180°C
- (-58°F ... 356°F)
Process pressure / max. overpressure limit
- Vacuum ... 25 bar
- (Vacuum ... 362 psi)
Main wetted parts
- PTFE, PA, 316L, Steel
Max. tensile strength
- 60 kN
Process connection
- Thread R1 1/2, NPT1 1/2
- Flanges from DN50.../ASME 2".../JIS...
Sensor length
- 0.5m ... 22m
- (1.6ft ... 72ft)
- Inactive length: 0.1m....1m
- (3"...39")
Communication
- 2- wire 19-253 VAC
- DC PNP
- Relais DPDT
- PFM
- 3-wire
- 8/16 mA
Certificates / Approvals
- ATEX, FM, CSA, IEC Ex, JPN Ex, NEPSI
Safety approvals
- SIL
Components
- PFM: FTC325, FTC625, FTC470Z, FTC471Z
- 3-wire: FTC325
Application limits
- DK min 2