Levelflex FMP50

Brand: Endress+Hauser

Levelflex FMP50

Brand: Endress+Hauser

Vector, Endress+Hauser's exclusive USA representative in:
Northwest AR South IL KS  MO East NM OK  TX

Heartbeat Technology Heartbeat Technology

Specs at a Glance

Main wetted parts:
Rod probe: 316L, PPS, Viton
Rope probe: 316, PPS, Viton
Max. measurement distance:
Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6
Process pressure / max. overpressure limit:
Vacuum...6 bar,
(Vacuum...87 psi)
Accuracy:
Rod probe: +/- 2 mm (0.08 in)
Rope probe: +/- 2 mm (0.08 in)
Process temperature:
-20...+80 °C
(-4...+176 °F)

Field of application

Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance. Particularly in basic supply or storage applications as well as utility processes FMP50 is the best choice. Levelflex FMP50 guided radar is used for continuous level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Specifications

Industry

  • Chemical
  • Water, Wastewater & Waste
  • Food & Beverage
  • Power & Energy
  • Mining, Minerals & Metals
  • Pulp & Paper (incl. Printing)

Product Family

  • Levelflex

Continuous / Liquids

Characteristic / Application

  • Basic device
  • Rod probe, Rope probe
  • Integrated data memory, Factory precalibrated, Reliable measuring for changing medias.

Specialities

  • Heartbeat Technology,
  • Bluetooth® commissioning,
  • Operation and maintenance SmartBlue App,
  • HistoROM,
  • RFID TAG for easy identification

Supply / Communication

  • 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
  • 4-wire (HART)
  • Bluetooth® wireless technology and App (optional)

Accuracy

  • Rod probe: +/- 2 mm (0.08 in)
  • Rope probe: +/- 2 mm (0.08 in)

Ambient temperature

  • -20...+80 °C
  • (-4...+176 °F)

Process temperature

  • -20...+80 °C
  • (-4...+176 °F)

Process pressure / max. overpressure limit

  • Vacuum...6 bar,
  • (Vacuum...87 psi)

Main wetted parts

  • Rod probe: 316L, PPS, Viton
  • Rope probe: 316, PPS, Viton

Process connection

  • Thread:
  • G 3/4, MNPT 3/4
  • Flange:
  • UNI Flange

Sensor length

  • Rod probe: 4 m (13 ft)
  • Rope probe: 12 m (40 ft)

Max. measurement distance

  • Rod: 4 m (13 ft) Min DK>1.6
  • Rope: 12 m (40 ft) Min DK>1.6

Communication

  • 4...20 mA HART
  • PROFIBUS PA
  • FOUNDATION Fieldbus
  • Bluetooth® wireless technology

Certificates / Approvals

  • ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex

Safety approvals

  • Overfill protection WHG
  • SIL

Design approvals

  • EN 10204-3.1

Options

  • Sensor remote with 3 m/ 9 ft cable,
  • Remote operation via SmartBlue App using Bluetooth®

Application limits

  • Application limits