Source Container FQG74

Brand: Endress+Hauser

Source Container FQG74

Brand: Endress+Hauser

Vector, Endress+Hauser's exclusive USA representative in:
Northwest AR South IL KS  MO East NM OK  TX

Xpert Xpert

Specs at a Glance

Process pressure / max. overpressure limit:
Any
Process temperature:
-52°C...+450°C
(-61°F...+842°F)
Main wetted parts:
Non-contact

Field of application

The source container FQG74 is designed to reliably hold up to 20 internal radioactive sources with highest activities during radiometric measurements. Thanks to the robust and high shielding, the source container is easy to use in straight and bent dip tube.

The source container FQG74 is used in combination with a radiometric transmitter for point level detection, continuous level and multipoint density measurement. It is suitable for applications with long measuring ranges.

Oil & Gas

Density profile measurement in the separation process

Level control of the catalyst bed across different elevations in the reactor for the hydrocracking process

Petrochemical / Chemical

Level or multipoint density measurement in reactors of the PTA and Urea process

Key Benefits

  • Best-in-class safety (Type A approval) and radiation protection
  • Easy commissioning of the sources – the source position can be adjusted individually by independent ropes (maximal rope length: 30 meters)
  • High shielding ensures that no control areas are generally required and that installation in accessible areas is possible
  • A high versatility with different variants of the source container enables the use in multiple applications
  • Padlock for fixation the on/off switch position and to protect against theft

Specifications

Industry

  • Chemical
  • Oil & Gas

Continuous / Liquids

Characteristic / Application

  • Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
  • Weight: 800 kg

Specialities

  • With flexible extension elements

Ambient temperature

  • -52°C...+120°C,
  • (-61°F...+248°F)

Process temperature

  • -52°C...+450°C
  • (-61°F...+842°F)

Process pressure / max. overpressure limit

  • Any

Main wetted parts

  • Non-contact

Process connection

  • Non-contact

Continuous / Solids

Characteristic / Application

  • Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
  • Weight: 800 kg

Specialities

  • With flexible extension elements

Ambient temperature

  • -52°C...+120°C,
  • (-61°F...+248°F)

Process temperature

  • -52°C...+450°C
  • (-61°F...+842°F)

Process pressure / max. overpressure limit

  • Any

Main wetted parts

  • Non-contact

Process connection

  • Non-contact

Density

Characteristic / Application

  • Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
  • Weight: 800 kg

Ambient temperature

  • -52°C.…+120°C
  • (-61°F.…+248°F)

Process temperature

  • -52°C.…+450°C
  • (-61°F.…+842°F)

Process pressure

  • Any

Wetted parts

  • Non-contact

Specialities

  • With flexible extension elements

Wetted materials

  • Non-contact

Measured variables

  • Density

Max. process pressure

  • Any

Point Level / Liquids

Characteristic / Application

  • Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
  • Weight: 800 kg

Specialities

  • With flexible extension elements

Ambient temperature

  • -52°C...+120°C,
  • (-61°F...+248°F)

Process temperature

  • -52°C...+450°C
  • (-61°F...+842°F)

Process pressure / max. overpressure limit

  • Any

Main wetted parts

  • Non-contact

Process connection

  • Non-contact

Point Level / Solids

Characteristic / Application

  • Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
  • Weight: 800 kg

Specialities

  • With flexible extension elements

Ambient temperature

  • -52°C...+120°C,
  • (-61°F...+248°F)

Process temperature

  • -52°C...+450°C
  • (-61°F...+842°F)

Process pressure / max. overpressure limit

  • Any

Main wetted parts

  • Non-contact

Process connection

  • Non-contact