Display / Indicator RID14
Brand: Endress+HauserDisplay / Indicator RID14
Brand: Endress+Hauser
Fundamental Specs at a Glance
Power Supply:
Not defined
Input:
Foundation Fieldbus protocol
PROFIBUS PA protocol
PROFIBUS PA protocol
Display:
High contrast backlit LCD with bargraph
TAG/unit
TAG/unit
Output:
Not defined
Field of application
The 8 channel indicator shows measured and calculated values, and status information of the fieldbus users in a FOUNDATION Fieldbus™ or PROFIBUS® PA network. In the listener mode the device listens to the set fieldbus addresses and indicates their values. In addition, for FOUNDATION Fieldbus™ values available on the bus can be indicated via function block interconnection. A plain text field allows the display of the engineering unit or of the TAG. A bargraph is available for trend visualization.
Key Benefits
- Brilliant, back lit LC display with bargraph, diagnostic symbols and clear text field.
- No external power supply required.
Specifications
Brand
Acquisition / Evaluation
Function
- Display values
- Advanced diagnostic
Certification
- ATEX Ex ia
- ATEX Ex d
- FM
- CSA
- IECEx Ex ia
- IECEx Ex d
- IECEx Ex tD
Input
- Foundation Fieldbus protocol
- PROFIBUS PA protocol
Dimensions (wxhxd)
- Field housing:
- 132 x 135 x 106 mm
- (5.2" x 5.31" x 4.17")
Software
- Listener Mode
- On Foundation Fieldbus also function block connection:
- Display transducer block
- Advanced diagnostic block´
- 2 x input selector
- Arithmetic block
- Integrator block
- PID block
Operation
- Foundation Fieldbus: via fieldbus
- PROFIBUS PA: DTM and FieldCare or DIP-switches on the device
- Write lock on hardware
Display
- High contrast backlit LCD with bargraph
- TAG/unit
Operating Voltage
- 9-32 V DC, polarity independent
Process indicator & control units
Measuring principle
- 8 channel field indicator for fieldbuses
Function
- Display values
- Advanced diagnostic
Display
- High contrast backlit LCD with bargraph
- TAG/unit
Power Supply
- Not defined
Input
- Foundation Fieldbus protocol
- PROFIBUS PA protocol
Output
- Not defined
Software functions
- Listener Mode
- On Foundation Fieldbus also function block connection:
- Display transducer block
- Advanced diagnostic block
- 2 x input selector
- Arithmetic block
- Integrator block
- PID block
Certificates
- ATEX II1G Ex ia IIC T6
- ATEX II3G Ex ic IIC T6
- ATEX II2G Ex db IIC T6 Gb
- ATEX II2D Ex tb IIIC Db
- ATEX II3G Ex nA IIC T6
- ATEX II1G Ex ia IIC T4/T5/T6, II2D
- CSA General Purpose
- CSA IS, NI I / 1+2/A-D
- CSA XP,NI,DIP I,II,III/1+2/A-G
- CSA XP,NI,DIP IS, NI I, II, III/1+2/A-G
- FM IS,NI I / 1+2/A-D
- FM XP,NI,DIP I,II,III/1+2/A-G
- FM XP,NI, DIP IS, NI I, II, III/1+2/A-G
- IECEx Ex ia IIC T6 Ga
- IECEx Ex db IIC T6 Gb
- IECEx Ex tb IIIC Db
SIL
- Not defined
Panel mounting
- field