Prosonic FDU9x FDU95

Brand: Endress+Hauser

Prosonic FDU9x FDU95

Brand: Endress+Hauser

Vector, Endress+Hauser's exclusive USA representative in:
Northwest AR South IL KS  MO East NM OK  TX

Extended Extended

Specs at a Glance

Main wetted parts:
UP (unsaturated polyester)
Process temperature:
-40 °C ... 80 °C
or 150 °C
(-40 °F ... 176 °F
or 302 °F)
Max. measurement distance:
45 m (148 ft)
Accuracy:
+/- 2mm + 0.17% of measured distance
Process pressure / max. overpressure limit:
0.7 bar...1.5 bar abs
(10 psi...22 psi)

Field of application

The FDU95 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of powdery to coarse bulk materials. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in solids 45m (148ft).

Key Benefits

  • Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present
  • Suited for rough ambient conditions thanks to separate installation from the transmitter (up to 300m)
  • Reduced build-up formation because of the self-cleaning effect
  • Integrated automatic sensor detection for transmitters FMU90/FMU95 for simple commissioning
  • Weather resistant and flood-proof (IP 68)

Specifications

Industry

  • Chemical
  • Power & Energy
  • Mining, Minerals & Metals

Product Family

  • Prosonic

Continuous / Liquids

Characteristic / Application

  • Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

Supply / Communication

  • 4-wire (HART, PROFIBUS DP)

Accuracy

  • +/- 2 mm + 0.17% of measured distance

Ambient temperature

  • -40 °C...80 °C
  • or 150 °C,
  • (-40 °F...176 °F
  • or 302 °F)

Process temperature

  • -40 °C...80 °C
  • or 150 °C,
  • (-40 °F...176 °F
  • or 302 °F)

Process pressure / max. overpressure limit

  • 0.7 bar...1.5 bar abs
  • (10 psi...22 psi)

Main wetted parts

  • UP (unsaturated polyester)

Process connection

  • G / NPT 1"

Blocking distance

  • 0.7 m / 80 °C,
  • (2.3 ft / 176 °F),
  • 0.9 m / 150 °C,
  • (2.9 ft / 302 °F)

Max. measurement distance

  • 45 m (148 ft)

Communication

  • Transmitter:
  • 4...20 mA HART
  • PROFIBUS DP

Certificates / Approvals

  • ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI,UK Ex

Options

  • Second 4...20 mA output

Components

  • Transmitter:
  • FMU90, FMU95

Continuous / Solids

Characteristic / Application

  • Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

Supply / Communication

  • 4-wire (HART, PROFIBUS DP)

Accuracy

  • +/- 2mm + 0.17% of measured distance

Ambient temperature

  • -40 °C ... 80 °C
  • or 150 °C
  • (-40 °F ... 176 °F
  • or 302 °F)

Process temperature

  • -40 °C ... 80 °C
  • or 150 °C
  • (-40 °F ... 176 °F
  • or 302 °F)

Process pressure / max. overpressure limit

  • 0.7 bar...1.5 bar abs
  • (10 psi...22 psi)

Main wetted parts

  • UP (unsaturated polyester)

Process connection

  • G / NPT 1"

Blocking distance

  • 0.7 m / 80 °C
  • (2.3 ft / 176 °F)
  • 0.9 m / 150 °C
  • (2.9 ft / 302 °F)

Max. measurement distance

  • 45 m (148 ft)

Communication

  • Transmitter:
  • 4 ... 20 mA HART
  • PROFIBUS DP

Certificates / Approvals

  • ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex

Options

  • Second 4...20mA output

Components

  • Transmitter:
  • FMU90
show more