EngyCal RS33
Brand: Endress+HauserEngyCal RS33
Brand: Endress+Hauser
Lean Specs at a Glance
Input:
1x Puls/Analog for flow
2x RTD/Analog for temperature and pressure
Loop power supply 24V DC (+/-16%)
2x RTD/Analog for temperature and pressure
Loop power supply 24V DC (+/-16%)
Display:
160 x 80 Dot-Matrix LCD with white backlit
colour change in case of alarm event
active display area 70 x 34 mm
colour change in case of alarm event
active display area 70 x 34 mm
Calculations:
IAPWS-IF97
Output:
1x 4...20mA
2x digital (Open Collector)
2x digital (Open Collector)
Field of application
The steam calculator EngyCal RS33 is used to record steam mass and energy flow of saturated and superheated steam. The calculation is based on the measured process variables volume flow, temperature and/or pressure.The EngyCal RS33 uses the standard IAPWS IF97 to calculate the mass and energy flow of steam. The density and enthalpy of the steam are calculated from the input variables pressure and temperature.
Recording and billing energy quantities in steam applications (steam heat quantity, steam heat differential). Typical applications include:
- Food industry
- Chemical industry
- Pharmaceutical industry
- Power plants
- Building systems and plant engineering
Key Benefits
- Compensation of differential pressure flow measurement
- Calculation according to international water steam tables
- Electronic matching of the temperature sensor (sensor-transmitter matching) with the arithmetic unit enables highly accurate temperature measurement
- Detailed data logging of current and counter values and of error messages, off-limit conditions and changes to operating parameters
- Standard models are suitable for connecting and supplying all common flow transmitters, temperature sensors and pressure sensors
- Remote readout via Ethernet and fieldbuses
- Deficit counter for transparency in case of error or alarm
Specifications
Brand
Industry
- Chemical
- Water, Wastewater & Waste
- Food & Beverage
- Power & Energy
- Mining, Minerals & Metals
- Oil & Gas
- Pulp & Paper (incl. Printing)
- Other industries
- Life Science
Product Family
- EngyCal
Energy & Application Manager
Measuring principle
- Energy manager
Function
- Monitoring and billing of energy in saturated and superheated steam applications (steam heat flow, heat difference.
- Typical applications can be found in food & beverage industry, chemical industry, pharmaceutical industry, power plants, building automation and skid builders.
Calculations
- IAPWS-IF97
Number of applications
- 1
Calculation standards
- IAPWS-97
Communication
- web server
- USB
- Ethernet
- Modbus RTU/TCP Slave
- M-Bus
Power supply
- Not defined
Loop power supply
- Low voltage power supply:
- 100 bis 230 V AC (-15% / +10%)
- Small voltage power supply:
- 24 V DC (-50% / +75%)
- 24 V AC (±50%)
Protection class
- IP65
Input
- 1x Puls/Analog for flow
- 2x RTD/Analog for temperature and pressure
- Loop power supply 24V DC (+/-16%)
Output
- 1x 4...20mA
- 2x digital (Open Collector)
Dimensions (WxHxD)
- 144 x 144 x 103.1 mm (5.67" x 5.67" x 4.06")
Operation
- 3 button on site or via FieldCare
- read out of historical / logged data via Field Data Manager Software (SQL database and visualization interface)
- selectable language
Display
- 160 x 80 Dot-Matrix LCD with white backlit
- colour change in case of alarm event
- active display area 70 x 34 mm
Software functions
- Calculated Values:
- Energy, volume, density, enthalpy, DP-Flow
- Counters:
- volume, mass, energy, counter in case of failure
- Optional:
- tariff 1, tariff 2 or seperated heating energy, cooling energy, bilance energy
Certificates
- MID 004 (custody transfer) according EN1434 (water/other liquids)
- OIML R75
Thermal Energy Measurement
Function
- Monitoring and billing of energy in saturated and superheated steam applications (steam heat flow, heat difference; typical applications can be found in food & beverage industry, chemical industry, pharmaceutical industry, power plants, building automation and skid builders
Certification
- CE, UL listed, CSA GP
Input
- 1x Puls/Analog for flow,
- 2x RTD/Analog for temperature and pressure,
- Loop power supply 24V DC (+/-16%)
Output
- 1x 4...20mA,
- 2x digital (Open Collector)
Relay output
- 2x
Auxiliary power supply
- Low voltage power supply: 100 bis 230 V AC (-15% / +10%); Small voltage power supply: 24 V DC (-50% / +75%), 24 V AC (±50%)
Dimensions (wxhxd)
- 144 x 144 x 103.1 mm
- (5.67" x 5.67" x 4.06")
Software
- Calculated Values:
- Energy, volume, density, enthalpy, DP-Flow;
- Counters: volume, mass, energy, counter in case of failure
- Optional: tariff 1, tariff 2 or seperated heating energy, cooling energy, bilance energy
Operation
- 3 button on site or via FieldCare; read out of historical / logged data via Field Data Manager Software (SQL database and visualization interface), selectable language
Display
- 160 x 80 Dot-Matrix LCD with white backlit, colour change in case of alarm event, active display area 70 x 34 mm
Others
- electronic temperature sensor matching via CvD coefficients, logbook measured values, custody transfer logbook, event logbook, limit monitoring
Calculations
- IAPWS-IF97