Xpert Specs at a Glance
Process pressure / max. overpressure limit:
Any
Process temperature:
-52°C...+450°C
(-61°F...+842°F)
(-61°F...+842°F)
Main wetted parts:
Non-contact
Field of application
The source container FQG74 is designed to reliably hold up to 20 internal radioactive sources with highest activities during radiometric measurements. Thanks to the robust and high shielding, the source container is easy to use in straight and bent dip tube.
The source container FQG74 is used in combination with a radiometric transmitter for point level detection, continuous level and multipoint density measurement. It is suitable for applications with long measuring ranges.
Oil & Gas
Density profile measurement in the separation process
Level control of the catalyst bed across different elevations in the reactor for the hydrocracking process
Petrochemical / Chemical
Level or multipoint density measurement in reactors of the PTA and Urea process
Key Benefits
- Best-in-class safety (Type A approval) and radiation protection
- Easy commissioning of the sources – the source position can be adjusted individually by independent ropes (maximal rope length: 30 meters)
- High shielding ensures that no control areas are generally required and that installation in accessible areas is possible
- A high versatility with different variants of the source container enables the use in multiple applications
- Padlock for fixation the on/off switch position and to protect against theft
Specifications
Brand
Industry
- Chemical
- Oil & Gas
Continuous / Liquids
Characteristic / Application
- Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
- Weight: 800 kg
Specialities
- With flexible extension elements
Ambient temperature
- -52°C...+120°C,
- (-61°F...+248°F)
Process temperature
- -52°C...+450°C
- (-61°F...+842°F)
Process pressure / max. overpressure limit
- Any
Main wetted parts
- Non-contact
Process connection
- Non-contact
Continuous / Solids
Characteristic / Application
- Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
- Weight: 800 kg
Specialities
- With flexible extension elements
Ambient temperature
- -52°C...+120°C,
- (-61°F...+248°F)
Process temperature
- -52°C...+450°C
- (-61°F...+842°F)
Process pressure / max. overpressure limit
- Any
Main wetted parts
- Non-contact
Process connection
- Non-contact
Density
Characteristic / Application
- Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
- Weight: 800 kg
Ambient temperature
- -52°C.…+120°C
- (-61°F.…+248°F)
Process temperature
- -52°C.…+450°C
- (-61°F.…+842°F)
Process pressure
- Any
Wetted parts
- Non-contact
Specialities
- With flexible extension elements
Wetted materials
- Non-contact
Measured variables
- Density
Max. process pressure
- Any
Point Level / Liquids
Characteristic / Application
- Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
- Weight: 800 kg
Specialities
- With flexible extension elements
Ambient temperature
- -52°C...+120°C,
- (-61°F...+248°F)
Process temperature
- -52°C...+450°C
- (-61°F...+842°F)
Process pressure / max. overpressure limit
- Any
Main wetted parts
- Non-contact
Process connection
- Non-contact
Point Level / Solids
Characteristic / Application
- Source container with flexible extension element to position up to 20 sources inside the process vessel (diptube)
- Weight: 800 kg
Specialities
- With flexible extension elements
Ambient temperature
- -52°C...+120°C,
- (-61°F...+248°F)
Process temperature
- -52°C...+450°C
- (-61°F...+842°F)
Process pressure / max. overpressure limit
- Any
Main wetted parts
- Non-contact
Process connection
- Non-contact