Display / Indicator RID14

Brand: Endress+Hauser

Display / Indicator RID14

Brand: Endress+Hauser

Vector, Endress+Hauser's exclusive USA representative in:
Northwest AR South IL KS  MO East NM OK  TX

Fundamental Fundamental

Specs at a Glance

Power Supply:
Not defined
Input:
Foundation Fieldbus protocol
PROFIBUS PA protocol
Display:
High contrast backlit LCD with bargraph
TAG/unit
Output:
Not defined

Field of application

The 8 channel indicator shows measured and calculated values, and status information of the fieldbus users in a FOUNDATION Fieldbus™ or PROFIBUS® PA network. In the listener mode the device listens to the set fieldbus addresses and indicates their values. In addition, for FOUNDATION Fieldbus™ values available on the bus can be indicated via function block interconnection. A plain text field allows the display of the engineering unit or of the TAG. A bargraph is available for trend visualization.

Key Benefits

  • Brilliant, back lit LC display with bargraph, diagnostic symbols and clear text field.
  • No external power supply required.

Specifications

Acquisition / Evaluation

Function

  • Display values
  • Advanced diagnostic

Certification

  • ATEX Ex ia
  • ATEX Ex d
  • FM
  • CSA
  • IECEx Ex ia
  • IECEx Ex d
  • IECEx Ex tD

Input

  • Foundation Fieldbus protocol
  • PROFIBUS PA protocol

Dimensions (wxhxd)

  • Field housing:
  • 132 x 135 x 106 mm
  • (5.2" x 5.31" x 4.17")

Software

  • Listener Mode
  • On Foundation Fieldbus also function block connection:
  • Display transducer block
  • Advanced diagnostic block´
  • 2 x input selector
  • Arithmetic block
  • Integrator block
  • PID block

Operation

  • Foundation Fieldbus: via fieldbus
  • PROFIBUS PA: DTM and FieldCare or DIP-switches on the device
  • Write lock on hardware

Display

  • High contrast backlit LCD with bargraph
  • TAG/unit

Operating Voltage

  • 9-32 V DC, polarity independent

Process indicator & control units

Measuring principle

  • 8 channel field indicator for fieldbuses

Function

  • Display values
  • Advanced diagnostic

Display

  • High contrast backlit LCD with bargraph
  • TAG/unit

Power Supply

  • Not defined

Input

  • Foundation Fieldbus protocol
  • PROFIBUS PA protocol

Output

  • Not defined

Software functions

  • Listener Mode
  • On Foundation Fieldbus also function block connection:
  • Display transducer block
  • Advanced diagnostic block
  • 2 x input selector
  • Arithmetic block
  • Integrator block
  • PID block

Certificates

  • ATEX II1G Ex ia IIC T6
  • ATEX II3G Ex ic IIC T6
  • ATEX II2G Ex db IIC T6 Gb
  • ATEX II2D Ex tb IIIC Db
  • ATEX II3G Ex nA IIC T6
  • ATEX II1G Ex ia IIC T4/T5/T6, II2D
  • CSA General Purpose
  • CSA IS, NI I / 1+2/A-D
  • CSA XP,NI,DIP I,II,III/1+2/A-G
  • CSA XP,NI,DIP IS, NI I, II, III/1+2/A-G
  • FM IS,NI I / 1+2/A-D
  • FM XP,NI,DIP I,II,III/1+2/A-G
  • FM XP,NI, DIP IS, NI I, II, III/1+2/A-G
  • IECEx Ex ia IIC T6 Ga
  • IECEx Ex db IIC T6 Gb
  • IECEx Ex tb IIIC Db

SIL

  • Not defined

Panel mounting

  • field
show more