Chlorine Sensors & Transmitters

Products for reliable measurement of chlorine and bromine-based disinfectants.

1 - 25 of 25 Products
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request a Quote
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request a Quote
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request a Quote
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request a Quote
Memosens CCS51E
Endress+Hauser
Memosens CCS51E
Extended Extended
Request a Quote
Sensor CCS51
Endress+Hauser
Sensor CCS51
Request a Quote
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request a Quote
Liquisys CCM253
Endress+Hauser
Liquisys CCM253
Request a Quote
Digital measuring cable Memobase CYK20
Endress+Hauser
Digital measuring cable Memobase CYK20
Request a Quote
Memosens CCS53E
Endress+Hauser
Memosens CCS53E
Extended Extended
Request a Quote
Digital measuring cable Measuring cable CYK10
Endress+Hauser
Digital measuring cable Measuring cable CYK10
Request a Quote
Memosens CCS58E
Endress+Hauser
Memosens CCS58E
Extended Extended
Request a Quote
Memosens CCS55E
Endress+Hauser
Memosens CCS55E
Extended Extended
Request a Quote
Memosens CCS50E
Endress+Hauser
Memosens CCS50E
Extended Extended
Request a Quote
Memocheck CYP02E
Endress+Hauser
Memocheck CYP02E
Request a Quote
Zero point gel Miscellaneous COY8
Endress+Hauser
Zero point gel Miscellaneous COY8
Request a Quote
Flowfit CYA27
Endress+Hauser
Flowfit CYA27
Request a Quote
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request a Quote
Liquiline, 4-wire CM448R
Endress+Hauser
Liquiline, 4-wire CM448R
Extended Extended
Request a Quote
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request a Quote
Flexdip CYA112
Endress+Hauser
Flexdip CYA112
Request a Quote
Memocheck CYP03D
Endress+Hauser
Memocheck CYP03D
Request a Quote
Measuring cable CYK11
Endress+Hauser
Measuring cable CYK11
Request a Quote
Liquisys CCM223
Endress+Hauser
Liquisys CCM223
Request a Quote
Sensor CCS50
Endress+Hauser
Sensor CCS50
Request a Quote

Disinfection and Chlorine Sensors and Transmitters

Endress+Hauser’s disinfection and chlorine portfolio couples amperometric Memosens sensors for free and total chlorine, chlorine dioxide, and free bromine with robust Liquiline and Liquisys transmitters and purpose‑built flow assemblies. The result is lab‑comparable, regulation‑aligned measurement brought online for reliable dose control and proof of compliance. Memosens 2.0 delivers digital, inductive coupling for moisture‑immune operation, on‑board calibration/data storage, and a solid basis for predictive maintenance. Typical targets span drinking water, process and reuse water, pool water, and seawater.

Free chlorine is covered by the Memosens CCS51D/CCS51E sensor family, specified for drinking water, utilities, and pool/process water with measuring ranges that cover trace to high levels. Because the HOCl/OCl⁻ equilibrium is pH‑dependent, Endress+Hauser provides integrated pH compensation via transmitters and assemblies designed to host both a chlorine and a pH/ORP sensor. Pair CCS51x with a pH sensor (e.g., CPS31E) in the Flowfit CCA250 assembly for stable bypass measurements; Liquisys CCM223/253 include built‑in pH compensation for free chlorine.

For chlorine dioxide and total chlorine, the Memosens CCS50E (ClO₂) and CCS53E (total chlorine) extend coverage to disinfection schemes beyond hypochlorite. CCS50E emphasizes fast, stable readings with low maintenance to optimize ClO₂ dosing or verify absence downstream of dosing/skids (e.g., beverage plants, RO). CCS53E continuously measures total chlorine, including long periods at true zero, making it a strong choice for residual checks in discharge, reuse, and process waters where “no chlorine present” must be proven. Both sensors leverage Memosens 2.0 for data integrity and simple handling.

Where bromination is preferred, especially in saline waters, Endress+Hauser offers the Memosens CCS55E for free bromine. Designed for desalination, cooling/process water, pools, and aquaculture, it provides high‑precision, fast response measurement and pairs with pH (when required) for compensation in seawater applications. Endress+Hauser also supplies pre‑engineered free‑bromine panels to accelerate deployment: prewired/piped assemblies with Memosens sensors and consistent sample hydraulics for stable readings and quick commissioning.

The transmitter layer simplifies control and integration. Liquiline CM442/CM444/CM448 multichannel platforms accept up to 2/4/8 Memosens sensors (chlorine, ClO₂, total Cl, bromine, pH/ORP and more), auto‑recognize sensors, and offer PID/controller and math modules to drive dosing systems directly. Heartbeat Technology supports diagnostics and verification to balance availability and service effort. For dedicated chlorine loops, Liquisys CCM223/253 provide a compact alternative with integrated pH compensation, modular I/O and fieldbus options, plus continuous plausibility and sensor checks.

Assemblies complete the measuring point. Flowfit CCA250 was purpose‑built for disinfection control: it houses the disinfection sensor and pH/ORP probes in one bypass body, adds flow adjustment/monitoring and a flow alarm to protect measurement readiness. For ClO₂ or apps that don’t need pH compensation, Flowfit CCA151 offers a simple, low‑flow holder. The newer Flowfit CYA27 is a modular multiparameter assembly (up to ~6 parameters) enabling flexible sensor positioning, integrated flow monitoring, and even cleaning/dosing modules, ideal for modern monitoring panels with minimal water loss.

In waterworks and wastewater, disinfection sensors underpin residual monitoring, distribution surveillance, and reuse compliance across chlorine, ClO₂, and bromine (and ozone where used). In industry, they protect RO pretreatment, cooling towers, and CIP/process‑water quality while avoiding overdosing. Endress+Hauser’s case applications show CCS51D monitoring at plant outlets, reservoirs, and networks to ensure residuals persist without excess dose. With Memosens digitalization, Liquiline/Liquisys control, and Flowfit hydraulics, the portfolio delivers traceable, auditable disinfection data that are easy to integrate, operate, and maintain.

Vector, your Authorized Endress+Hauser Representative