Conductivity Sensors & Transmitters

Products for high precision conductivity measurement in all industries.

1 - 48 of 51 Products
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request a Quote
CLY421
Endress+Hauser
CLY421
Request a Quote
Conductivity sensor Memosens CLL47E
Endress+Hauser
Conductivity sensor Memosens CLL47E
Request a Quote
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request a Quote
Memosens CLS82E
Endress+Hauser
Memosens CLS82E
Extended Extended
Request a Quote
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request a Quote
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request a Quote
Memobase CYZ71D
Endress+Hauser
Memobase CYZ71D
Request a Quote
Hand held CYM290
Endress+Hauser
Hand held CYM290
Request a Quote
Flowfit CYA21
Endress+Hauser
Flowfit CYA21
Request a Quote
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request a Quote
Condumax CLS12
Endress+Hauser
Condumax CLS12
Request a Quote
Memosens CLS16E
Endress+Hauser
Memosens CLS16E
Extended Extended
Request a Quote
Flowfit CPA25
Endress+Hauser
Flowfit CPA25
Lean Lean
Request a Quote
Transmitter Liquiline, 2-wire CM82
Endress+Hauser
Transmitter Liquiline, 2-wire CM82
Request a Quote
Condumax CLS15
Endress+Hauser
Condumax CLS15
Request a Quote
Digital measuring cable Memobase CYK20
Endress+Hauser
Digital measuring cable Memobase CYK20
Request a Quote
Digital measuring cable Measuring cable CYK10
Endress+Hauser
Digital measuring cable Measuring cable CYK10
Request a Quote
Transmitter Liquiline, 2-wire CM42
Endress+Hauser
Transmitter Liquiline, 2-wire CM42
Extended Extended
Request a Quote
Memosens CLS21E
Endress+Hauser
Memosens CLS21E
Extended Extended
Request a Quote
Smartec CLD132
Endress+Hauser
Smartec CLD132
Request a Quote
Hand held CYM291
Endress+Hauser
Hand held CYM291
Request a Quote
Condumax CLS16B
Endress+Hauser
Condumax CLS16B
Extended Extended
Request a Quote
In-line Photometer CYA680
Endress+Hauser
In-line Photometer CYA680
Request a Quote
Memocheck CYP02E
Endress+Hauser
Memocheck CYP02E
Request a Quote
Flowfit CYA27
Endress+Hauser
Flowfit CYA27
Request a Quote
Conductivity sensor Smartec CLD134
Endress+Hauser
Conductivity sensor Smartec CLD134
Extended Extended
Request a Quote
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request a Quote
Liquiline, 4-wire CM448R
Endress+Hauser
Liquiline, 4-wire CM448R
Extended Extended
Request a Quote
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request a Quote
Transmitter Liquiline, 4-wire CM14
Endress+Hauser
Transmitter Liquiline, 4-wire CM14
Fundamental Fundamental
Request a Quote
Condumax CLS19
Endress+Hauser
Condumax CLS19
Request a Quote
Conductivity sensor Indumax CLS50
Endress+Hauser
Conductivity sensor Indumax CLS50
Request a Quote
Conductivity sensor Indumax CLS50D
Endress+Hauser
Conductivity sensor Indumax CLS50D
Extended Extended
Request a Quote
Flexdip CYH112
Endress+Hauser
Flexdip CYH112
Request a Quote
Flexdip CYA112
Endress+Hauser
Flexdip CYA112
Request a Quote
Conductivity sensor Memosens CLS15E
Endress+Hauser
Conductivity sensor Memosens CLS15E
Extended Extended
Request a Quote
Indumax CLS54D
Endress+Hauser
Indumax CLS54D
Extended Extended
Request a Quote
Condumax CLS13
Endress+Hauser
Condumax CLS13
Request a Quote
Memocheck CYP03D
Endress+Hauser
Memocheck CYP03D
Request a Quote
Dipfit CLA111
Endress+Hauser
Dipfit CLA111
Request a Quote
Conductivity sensor Indumax CLS54
Endress+Hauser
Conductivity sensor Indumax CLS54
Request a Quote
Conductivity sensor Condumax CLS21
Endress+Hauser
Conductivity sensor Condumax CLS21
Request a Quote
Measuring cable CYK11
Endress+Hauser
Measuring cable CYK11
Request a Quote
Liquisys CLM223
Endress+Hauser
Liquisys CLM223
Request a Quote
Dipfit CLA140
Endress+Hauser
Dipfit CLA140
Request a Quote
Indumax CLS52
Endress+Hauser
Indumax CLS52
Request a Quote
Liquisys CLM253
Endress+Hauser
Liquisys CLM253
Request a Quote

Conductivity Sensors & Transmitters

Endress+Hauser’s conductivity portfolio pairs rugged Memosens sensors, covering conductive (2‑electrode), 4‑electrode, and inductive/toroidal principles, with scalable Liquiline and Liquisys transmitters. This breadth lets you instrument everything from trace‑level pure water to highly concentrated acids, caustics, and brines, using hygienic or process connections as required. The Liquiline platform adds Heartbeat diagnostics/verification and modular I/O/fieldbuses, while Memosens 2.0 ensures moisture‑immune, digitally calibrated operation. Selection guidance is straightforward: conductive for low conductivities, 4‑electrode for wide ranges, and toroidal for high/dirty media.

2‑electrode (contacting) sensors address low to medium ranges and pure water. Memosens CLS15E targets trace/low conductivity, e.g., boiler feedwater and RO permeate, and supports resistivity reporting via Liquiline transmitters, simplifying SWAS deployments. Memosens CLS21E is the robust generalist for water applications with medium conductivities. For sanitary processes and life sciences, Memosens CLS16E adds high‑end hygienic design (FDA/USP Class VI) and precise temperature compensation for repeatable phase control and final rinse verification. All benefit from Memosens 2.0 for predictive maintenance and lab calibration workflows.

4‑electrode sensors extend dynamic range and reduce polarization, making them ideal when one probe must span clean‑in‑place (CIP) chemicals, product, and final rinse. Memosens CLS82E is a hygienic, compact 4‑electrode sensor designed for processes with widely varying conductivity; typical duties include phase separations, chromatography, fermentations, ultrafiltration, and CIP in small pipes. For aggressive or sticky media where non‑fouling is critical, or conductivity is very high, use inductive/toroidal designs: Indumax CLS50D (PFA/PEEK) for harsh chemical service and high temperature; Indumax CLS54D for hygienic/sterile applications in food, beverage, and pharma, including CIP return control and product/water transitions.

On the transmitter side, Liquiline CM442/CM444/CM448 accept 2/4/8 digital Memosens sensors in any mix (conductivity, pH/ORP, DO, disinfection, and more), auto‑recognize probes, and expose controller/math modules for dosing or derived variables (e.g., TDS/salinity). Connectivity spans HART, PROFIBUS, Modbus, and EtherNet/IP with an integrated web server for remote access; Heartbeat Technology underpins on‑demand verification and diagnostics. Rail‑mount variants (CM44xR) add cabinet‑friendly packaging for skid or panel builds.

For compact and loop‑powered points, Liquiline Compact CM82 plugs directly onto a Memosens sensor to create a 2‑wire measuring point with Bluetooth® commissioning, handy in space‑constrained or retrofit locations; a CM82+RIA46 bundle lets you power two head transmitters from a 4‑wire field meter. Liquiline CM14 is the cost‑efficient 4‑wire panel unit for standard water/wastewater panels. Where a rugged 2‑wire field transmitter is preferred, Liquiline M CM42 covers demanding environments (hygienic, Ex, SIL) and integrates over HART/PA/FF.

Portfolio benefits center on measurement integrity and lifecycle cost. Memosens’ inductive, non‑contact connector eliminates moisture ingress and stores calibration/sensor data for swap‑and‑go maintenance; Liquiline provides uniform commissioning, diagnostics, and spare‑part commonality across parameters. Factory‑measured, certified cell constants and available calibration standards help maintain traceability. For pharma waters, Liquiline implements USP <645> / EP limit functions using uncompensated conductivity with temperature tables, supporting WFI/HPW/PW compliance checks out of the box.

Applications span utilities and core process control. In power and microelectronics, CLS15E+Liquiline measure conductivity/resistivity in ultrapure water, RO/CEDI, and condensate, with alarm logic to protect assets. In food & beverage and life sciences, CLS82E or CLS16E support hygienic phase separation and CIP verification; CLS54D serves CIP return lines where toroidal immunity to coating and high caustic conductivity is valuable. In chemicals, Indumax CLS50D handles acids, bases, and brine strength control at elevated temperature. For water & wastewater, CLS21E with CM14/CM44x provides salinity/TDS trending, leak detection, blending control, and network monitoring, on skids or in distributed panels.

Vector, your Authorized Endress+Hauser Representative